Journal of Lipid Research, Vol. 48, 2079-2085, September 2007
Specific and rapid analysis of ubiquinones using Craven's reaction and HPLC with postcolumn derivatization
* Frontier Science Laboratories, H&BC Development Center, Shiseido Co., Ltd., Kanazawa, Yokohama 236-8643, Japan Published, JLR Papers in Press, June 20, 2007.
1 To whom correspondence should be addressed. e-mail: haruo.shimada{at}to.shiseido.co.jp
A new method for the analysis of ubiquinones in various samples was developed using an HPLC system with postcolumn derivatization. Craven's reaction, a specific color reaction for the analysis of ubiquinones, was used in the system. Because the reaction progressed in organic solvents that contained ubiquinones and ethylcyanoacetate under an alkaline condition, the selectivity for ubiquinone detection was higher than that for ubiquinone detection using the nonderivatized ultraviolet detection system at 275 nm, a system widely used for the analysis of ubiquinones. The new detection system can avoid the adverse effects of impurities. Furthermore, it can confirm specificity by stopping the color reaction under a neutral condition. The detection limit for ubiquinone-10 was 1 ng (1.2 pmol). A good linearity for the calibration curve was observed in the range of 11.7 pmol to 11.7 nmol. To investigate the possible application of this method, various samples, such as soybean capsules used as a dietary supplement and biological materials (rice as well as bovine plasma and liver samples), were applied to the system and their ubiquinone contents were quantified. This method is thought to be widely and conveniently applicable for determining the level of ubiquinones because of its high selectivity for ubiquinone detection.
Supplementary key words quantification high-performance liquid chromatography coenzyme Q9 and Q10 Abbreviations: RSD, relative standard deviation
Ubiquinone, also known as coenzyme Q, belongs to the fat-soluble component in aerobic organisms and is widely distributed in nature with varying lengths of the side chain isoprene units (1, 2). Ubiquinone is important as an electron carrier in the mitochondrial electron transport system (1, 3, 4) and is useful for producing ATP. Ubiquinone-10, which has 10 isoprene units, is particularly important because it is found in the human mitochondrial respiratory chain. Ubiquinones are indispensable components for the maintenance of normal cellular functions, and their other biological functions, such as antioxidant functions, have been discussed (5–13). Rosenfeldt et al. (14) concluded that ubiquinone-10 administration improves the recovery of the mitochondrion and cardiac myocyte from stress. Thus, recently, various products containing ubiquinone-10 have been widely distributed, namely, foods for promoting body function, dietary supplements, cosmetics, and pharmaceutical products. The general methods for the determination of the amount of ubiquinones in a substance are HPLC with ultraviolet detection (15–18) and HPLC with electrochemical detection (19–23). Electrochemical detection is used for high-sensitivity detection, whereas ultraviolet detection is most widely used because of its ease of application. The appropriate ubiquinone detection method should be selected depending on the purpose of the analysis. Other methods for ubiquinone analysis have also been studied (24–27). However, in some cases, much of the time involved in carrying out ubiquinone analysis is spent avoiding the adverse effects of impurities. Thus, the specificity of the detection method is important for the quantification of ubiquinones. Although there have been many opportunities for the analysis of various samples containing ubiquinones (e.g., ubiquinone-containing products and biological materials), the development of a widely usable analysis method for ubiquinones has been difficult. Various products and biological materials may contain many impurities that interfere with ubiquinone detection, and the contents of ubiquinones in various samples also differ. To overcome these constraints, we have applied a highly selective detection system for ubiquinones using an HPLC separation system and developed a new method of ubiquinone analysis for various products and biological materials. Craven's reaction, a specific color reaction for quinones, was first reported by Craven in 1931 (28) and has been applied to the quantitative determination of ubiquinones (26, 27). This color reaction produces a blue product by displacing the methoxyl moieties of ubiquinones to active methylene compounds such as ethylcyanoacetate under an alkaline condition (29, 30). However, it is difficult to quantify the exact amount of ubiquinone accurately, because the blue product is not stable in the reaction mixture. Blue changes to green in several minutes (29). Moreover, Craven's reaction cannot distinguish specific ubiquinone species. To overcome these problems, Craven's reaction was applied to an HPLC postcolumn on-line system. The color reaction is fixed because it can be set to a suitable time in the reaction tube (the reaction time is dependent on the tube volume). Ubiquinone species, such as ubiquinone-9 and ubiquinone-10, can also be separated using an analytical column and distinguished by determining the retention time of each species. To assemble the HPLC ubiquinone detection system, expensive devices are not needed. To investigate the possible application of this method, various samples containing ubiquinones were tested using the system and their ubiquinone contents were quantified accurately. Ubiquinone-10-containing capsules are widely distributed in the health food industry as a dietary supplement. However, detailed information on the contents of each product is not open to the public. Moreover, it is difficult to obtain a placebo sample, which is useful for validating the analytical method. Accordingly, we developed a ubiquinone-10-containing soybean capsule and a placebo sample using the methods of Andersson (16). Samples obtained from a soybean capsule were tested using the system, and the accuracy and precision of the new method were investigated. To determine the ubiquinone content of biological materials, rice samples at two polishing stages were used as food samples, and bovine plasma and liver samples were used as mammalian samples. In this study, we aim to develop a specific method to accurately determine the ubiquinone content of various samples, such as dietary supplements and biological materials.
Chemicals HPLC-grade methanol, ethanol, chloroform, and hexane as well as ethylcyanoacetate were purchased from Wako Pure Chemical Industries, Ltd. (Osaka, Japan). All other chemicals were of analytical grade. Bovine plasma and liver samples were purchased from Funakoshi Co., Ltd. (Tokyo, Japan), and Tokyo Shibaura Zouki Co., Ltd. (Tokyo, Japan), respectively. The polished rice and brown rice (Koshihikari) were generous gifts from Mr. T. Ikeda.
HPLC apparatus and construction of the postcolumn derivatization system
Characterization of the method To confirm the effect of Craven's reaction, 234 pmol (202 ng) of ubiquinone-10 (Table 1 ) was applied to the system (reaction condition). Subsequently, the sample was reanalyzed using water-ethanol (3:2, v/v) instead of the reaction solution (nonreaction condition).
To investigate the detection limit and dynamic range for ubiquinone quantification, 1 mg/ml ubiquinone-10 was prepared in ethanol-n-hexane (95:5, v/v), and the solution was diluted to a suitable concentration from 0.03 to 504 µg/ml with the solution from the mobile phase, as shown in Table 1. The possibility for ubiquinone quantification was considered by determining the linearity of the calibration curve. To investigate repeatability, 117 pmol (101 ng) of ubiquinone-10 was applied repeatedly six times to the system.
Extraction of ubiquinone-10 from the soybean capsule The capsule was opened and 50 ml of the n-hexane was poured into a volumetric flask using a funnel. Two and one-half milliliters of the solution was taken and diluted to a final volume of 50 ml with 1.2 mM FeCl3 in ethanol-methanol (1:1, v/v). After allowing ubiquinol oxidation to occur (2 h), 20 µl of each sample was applied to the system. For ubiquinone quantification, standard solutions of 5, 15, 30, 50, and 75 µg/ml ubiquione-10 were also prepared.
Extraction of ubiquinones from rice samples
Extraction of ubiquinones from bovine plasma
Extraction of ubiquinones from bovine liver
Characterization of the method The theoretical reaction time (0.91 min) was calculated from the flow rate (those for pumps A and B were 0.4 and 0.06 ml/min, respectively) and volumes of the reaction coil (368 µl) and mixer (50 µl). The effect of Craven's reaction on the HPLC postcolumn derivatization system was confirmed by analyzing the content of ubiquinone-10 under the reaction condition, in which potassium hydroxide (0.4 M) in water-ethanol (3:2, v/v) was used as the pump B solution (Fig. 2A ), and the nonreaction condition, wherein potassium hydroxide was removed from the solution (Fig. 2B). Because one peak (11.5 min) was observed in the chromatogram under the reaction condition and no peak was observed in the chromatogram under the nonreaction condition, derivatization was thought to be achieved using the system. The wavelength for the ubiquinone detection was determined to be 635 nm from the spectrum of the peak at 11.5 min (Fig. 2C). To investigate the dynamic range of ubiquinone concentration detection, solutions with a wide variety of ubiquinone-10 concentrations were prepared (Table 1). The detection limit, based on a signal-to-noise ratio of 3:1, was 1.2 pmol (1 ng). Because the lower limit of quantification, based on a signal-to-noise ratio of 10:1 [with an accuracy of 106.4% and a relative standard deviation (RSD) of 2.54%; n = 6], was 11.7 pmol (10 ng), the calibration curve was plotted using an injection amount from 11.7 pmol (10 ng) to 11.7 nmol (10 µg), as shown in Table 1 (y = 209.47x – 2,319; r2 = 1.0000). The correlation coefficient (r2 = 1.0000) indicates that the calibration curve is linear over the concentration range. The RSD of the standard solution at an injection amount of 117 pmol obtained from six experiments was 0.46% (the average of the peak area was 23,517).
Analysis of ubiquinone-10 from the soybean capsule Soybean capsules containing ubiquinone-10 are widely distributed in the health food industry as a dietary supplement. Figure 3A , C show the chromatograms of the ubiquinone-10 contained in a soybean capsule under the reaction and nonreaction conditions, respectively. Figure 3B shows the chromatogram of a placebo sample under the reaction condition. Because no peaks were observed in the chromatogram of the placebo sample (Fig. 3B) under the reaction condition or in the chromatogram of the ubiquinone-10-containing capsule under the nonreaction condition (Fig. 3C), it was considered that no impurity affecting ubiquinone detection was present in the capsule. The chromatograms obtained from the removal of the analytical column are shown in Fig. 3D–F. No peak was observed when the nonreaction solution was used (Fig. 3F) or when the placebo sample was analyzed (Fig. 3E). The intraday recovery and RSD results obtained using the soybean capsule samples with the analytical column are shown in Table 2 . The recovery and RSD results obtained at each known concentration of ubiquinone-10 were quite good (99.1–100.2% and 0.25–1.24%, respectively). Interday recovery and repeatability studies were carried out for 3 days using the 30 mg/capsule samples (five experiments for each day). The interday recovery and RSD results were also quite good (99.80% and 0.52%, respectively). These results indicate that the new method can be used to accurately quantify the ubiquinone.
The recovery test results obtained from the ubiquinone quantification at 30 mg/capsule with and without the analytical column were similar (99.9 ± 0.30% and 100.7 ± 0.59%, respectively). The calibration curves plotted using results obtained with and without the analytical column were both linear (y = 205.0x + 27.9, r2 = 1.0000 and y = 210.1x – 1221.7, r2 = 1.0000, respectively). In the case of the analysis of ubiquinone-10 in the capsule, there was no need for column separation. Thus, ubiquinone quantification can be performed rapidly without the analytical column (within 3 min). Because various ubiquinone-10-containing products have been distributed on the market recently, the use of the analytical column may depend on the composition of each product. Although specificity should be confirmed before ubiquinone quantification, specificity can be achieved easily using the nonreaction solution. This is a unique feature of the postcolumn derivatization method.
Application to rice samples
To confirm the efficiency of our extraction method, the residues remaining after the polished rice and brown rice extractions were reextracted carefully using the same procedure and analyzed using the new system. No peak was observed in any of the chromatograms of the reextraction samples. Thus, the extraction is considered to be efficient. The calibration curve obtained from the ubiquinone quantification was also linear (y = 201.7x + 26.5, r2 = 0.9998). The amounts of ubiquinone-9 and ubiquinone-10 in the two rice samples are shown in Table 3 . The RSDs of ubiquinone-9, the dominant ubiquinone of rice, for polished rice and brown rice were 2.1% and 1.1%, respectively. The extraction efficiency was constant. The amounts of ubiquinones decrease as a result of rice cleaning. In the case of the conventional condition (ultraviolet detection at 275 nm), the amount of each ubiquinone was not determined owing to the many impurities present, and an analysis time of >20 min may be needed to avoid contamination in the next analysis (Fig. 5 ).
Application to bovine plasma and liver samples Ubiquinone analysis of the bovine plasma and liver samples was performed using the system. The chromatograms of the bovine plasma and liver samples are shown in Fig. 4E–H. An impurity peak was not shown by these samples because no interference peak was observed in their chromatograms under the nonreaction condition (Fig. 4F, H). Because no ubiquinone peaks were observed in the chromatograms of the reextraction samples obtained from the residues remaining after the extraction of bovine plasma and liver samples, the extraction is considered to be efficient. The total amounts of ubiquinone-9 and ubiquinone-10 in the samples are shown in Table 3. The RSDs of ubiquinone-10, the dominant ubiquinone of bovine samples, for bovine plasma and liver samples were 1.9% and 4.4%, respectively. The extraction efficiency was constant. It was difficult to determine the amounts of ubiquinones by ultraviolet detection at 275 nm because of the impurities present (data not shown). The postcolumn derivatization system is effective for determining the total amounts of ubiquinones without incurring much expense. Because of the high selectivity of the system, various products, namely, the soybean capsule and food and animal biomaterials, were analyzed under the same HPLC analysis condition, and the amount of each ubiquinone was quantified accurately. Many ubiquinone-10-containing products contain only ubiquinone-10 as their quinone component. If the impurities that interfere with the quantification are not contained in these products, there is no need to separate the quinone components. Thus, for these products, the use of an analytical column is not needed and the analysis time can be decreased to 3 min. This method may be advantageous for the simple determination of the total amount of ubiquinone in various products and foods.
The authors thank Mr. T. Ikeda for providing the rice samples and Mrs. A. Kotaka for her skillful technical assistance.