J. Lipid Res.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Originally published In Press as doi:10.1194/jlr.D300024-JLR200 on October 16, 2003

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
D300024-JLR200v1
45/2/396    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Mizoguchi, T.
Right arrow Articles by Koshi, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mizoguchi, T.
Right arrow Articles by Koshi, T.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

Journal of Lipid Research, Vol. 45, 396-401, February 2004
Copyright © 2004 by American Society for Biochemistry and Molecular Biology


Methods

A method of direct measurement for the enzymatic determination of cholesteryl esters

Toshimi Mizoguchi1, Toshiyuki Edano and Tomoyuki Koshi

Tokyo New Drug Research Laboratories II, Pharmaceutical Division, Kowa Co. Ltd., Tokyo 189-0022, Japan

1 To whom correspondence should be addressed. e-mail: t-mizogt{at}kowa.co.jp

A direct measurement method for the enzymatic determination of cholesteryl esters (CEs) without measuring total cholesterol (TC) and free cholesterol (FC) is described. In the first step, hydrogen peroxide generated by cholesterol oxidase from FC was decomposed by catalase. In the second step, CE was measured by enzymatic determination using a colorimetric method or a fluorometric method. The measurement sensitivity of the fluorometric method was more than 20 times that of the colorimetric method. Optimal conditions of the assay were determined, and examples of measured CE in human plasma, rat liver, and cultured cells are indicated.

The method of directly measuring CE was simple and has exceptional reproducibility compared with the technique of subtracting FC from TC using each measured TC and FC.

Supplementary key words cholesterol assay • cholesterol oxidase catalase • plasma • liver • tissue culture


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
J. Virol.Home page
M. Prior, S. Lehmann, M.-S. Sy, B. Molloy, and H. E. M. McMahon
Cyclodextrins Inhibit Replication of Scrapie Prion Protein in Cell Culture
J. Virol., October 15, 2007; 81(20): 11195 - 11207.
[Abstract] [Full Text] [PDF]


Home page
J. Nutr.Home page
C. T. Damsgaard, L. Schack-Nielsen, K. F. Michaelsen, M.-B. Fruekilde, O. Hels, and L. Lauritzen
Fish Oil Affects Blood Pressure and the Plasma Lipid Profile in Healthy Danish Infants
J. Nutr., January 1, 2006; 136(1): 94 - 99.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 All ASBMB Journals   Journal of Biological Chemistry 
 Molecular and Cellular Proteomics   ASBMB Today 
Copyright © 2004 by the American Society for Biochemistry and Molecular Biology.