Advertisement
J. Lipid Res.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 QUICK SEARCH:   [advanced]


     


A more recent version of this article appeared on August 1, 2005

Papers In Press, published online ahead of print March 16, 2005
J. Lipid Res., doi:10.1194/jlr.D500002-JLR200
This Article
Right arrow Full Text (Accepted Manuscript)
Right arrow All Versions of this Article:
D500002-JLR200v1
46/8/1786    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Neyer, J.
Right arrow Articles by Rajavashisth, P. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Neyer, J.
Right arrow Articles by Rajavashisth, P. B.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

Submitted on January 13, 2005
Revised on February 23, 2005
Accepted on March 10, 2005

A comparison of anion exchange and steric exclusion HPLC assays of mouse plasma lipoproteins

Jonathan Neyer, Christain Espinoza, Terence M. Doherty, Luppe Luppen, Subhash C. Tripathi, Hiroyasu Uzui, Pinky V. Tripathi, Gerald Lee, Prediman K. Shah, and Prediman B. Rajavashisth

Medicine Dept., Cedars-Sinai Medical Center, Los Angeles, CA 90048, CA

Corresponding Author: rajavashisth{at}cshs.org

We compared the precision and accuracy of two HPLC methods (anion exchange [AE] and steric exclusion [SE]) for analysis of mouse lipoprotein profiles by determining coefficients of variability (CVs) under varying conditions. CVs for AE and SE were comparable on fresh samples (average CVs 7.7 ± 6.2% and 5.8 ± 2.7% for AE and SE respectively). There was an inverse linear relationship between subfraction curve area and CV (r = -0.65 [AE] and –0.50 [SE]), consistent with interpretation that as curve area decreased, error variance increased and signal-to-noise ratio decreased. Sample storage did not affect SE. In contrast, with AE, alterations in measured lipoproteins were apparent after 7 days storage, including a decrease in the HDL subfraction (66.8% [baseline] vs. 15.9% [1 week]; p < 0.01) and an increase in areas under LDL and VLDL peaks (LDL: 23.4% vs. 42.1% , VLDL: 9.9% vs. 41.9% [1 week vs. baseline for both comparisons; p < 0.02 and p < 0.03 respectively]). Concomitant with decreasing HDL area, reproducibility deteriorated with duration of storage. Analysis of the effects of decreasing sample injectate volume below 25 mL on SE lipoprotein subfractions revealed that area under LDL and VLDL peaks decreased (26.8% and 25.4% respectively; p < 0.001) and persisted as volume was decreased further. Areas under all lipoprotein subfractions measured with either AE or SE were linearly correlated with the amount of cholesterol measured by a colorimetric assay (r = 0.69 [AE] and 0.87 [SE]). Both AE and SE yield reproducible, accurate, and rapid measurements of lipoproteins from small amounts of serum. AE yields more sensitive, high amplitude, well-defined peaks that can be easily distinguished, and necessitates the use of smaller sample volumes compared to SE, but sample storage causes alterations in the chromatogram. SE appears better suited to serial analyses involving stored samples.


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 All ASBMB Journals   Journal of Biological Chemistry 
 Molecular and Cellular Proteomics   ASBMB Today 
Copyright © 2005 by the American Society for Biochemistry and Molecular Biology.
Advertisement
spacer
Advertisement
Advertisement